Digitrax Stationary Decoder CVs

DS54

 
 
Output Control
CV# Description Click
03 Output type for A  For Chart
04 Output type for B
05 Output type for C
06 Output type for D
 
 
Trigger/Task Codes
CV# Usage Color Click
33 Aux A Input Orange  For Chart
34 Switch A Input  Blue
35 Aux B Input Black
36 Switch B Input Violet
37 Aux C Input Yellow
38 Switch C Input Gray
39 Aux D Input Green
40 Switch D Input Red
 
Message Type
CV# Message Type Click
41 Aux A Input Message For Chart
42 Switch A In/Output
43 Aux B Input Message
44 Switch B In/Output
45 Aux C Input Message
46 Switch C In/Output
47 Aux D Input Message
48 Switch D In/Output
 
 
Local Route Control
CV# Local Input  Color Click
49 Aux A Input  Orange  For Chart
50 Switch A  Input  Blue
51 Aux B Input Black
52 Switch B Input Violet
53 Aux C Input Yellow
54 Switch C Input Gray
55 Aux D Input Green
56 Switch D Input Red
 
Cascade Request
CV# Control Value
57 Aux A Control No Cascade 
Message   (00) 

Throw Turnout 
OFF         (90) 

Close Turnout 
ON          (B0)

59 Switch A Control 
61 Aux B Control
63 Switch B Control
65 Aux C Control
67 Switch C Control
69 Aux D Control
71 Switch D Control
 
Cascade Request
CV# Address Value
58 Aux A Address
Valid Range 00 to 7F

Turnout Address -1 in
Hexadecimal. 

Ex: Turnout #1 has
Cascade Address of
#00
60 Switch A Address
62 Aux B Address
64 Switch B Address
66 Aux C Address
68 Switch C Address
70 Aux D Address
72 Switch D Address
 

Output Type Chart
Solenoid/Retriggerable Duration Value Solenoid/No-Retrigger Duration Value Static/Blink Duration Value
Retriggerable means 
the DS54 will take 
another action before 
the first trigger action 
is completed.
0.125 sec 00 No-Retrigger means 
the DS54 will throw 
out all additional 
trigger action till the 
initial trigger action is 
completed.
0.125 sec 10 Static Steady 20
0.250 sec 01 0.250 sec 11 Blinking 0.125 sec 21
0.350 sec 02 0.350 sec 12 0.250 sec 22
0.500 sec 03 0.500 sec 13 0.500 sec 23
0.625 sec 04 0.625 sec 14 1.000 sec 24
0.750 sec 05 0.750 sec 15 2.000 sec 25
0.900 sec 06 0.900 sec 16 4.000 sec 26
1.000 sec 07 1.000 sec 17 8.000 sec 27
2.000 sec 08 2.000 sec 18
3.000 sec 09 3.000 sec 19
4.000 sec 0A 4.000 sec 1A
5.000 sec 0B 5.000 sec 1B
6.000 sec 0C 6.000 sec 1C
7.500 sec 0D 7.500 1D
10.00 sec 0E 10.00 sec 1E
12.00 sec 0F 12.00 sec 1F

Trigger/Task Chart
Trigger Polarity Event When 1st Digit
Value
Task Action Used for 2nd digit
Value
Input on Off to On Positive Edge 0x Output Toggle Manual Control x0
Input off On to Off Negative edge 8x No Output Change  No Affect x1
Input on Any Change  Positive edge 1x Output On Thrown Turnout x2
Input off Any Change Negative edge  9x Output Off Closed  Turnout x3
Qualified 
by Output
Output on 
Output off
Positive edge 
Negative edge
2x Output Clear No output power x4
Qualified 
by Output
If output on 
If output off
Positive edge 
Negative edge
3x Restore previous Continue x5
Execute 
local route
Local route control  x6
Output 
follows input
Turnout follows 
input polarity
x7

Message Type Chart
LocoNet Message Sent Results Value
Sensor Input Message Input treated as general sensor. 00
No LocoNet Message No messages at all. 01
Turnout Feedback Message Input is turnout position feedback. 02
Cascaded Turnout Request Send cascade turnout request msg. 03
System Power On/Off Send ON/OFF based on trigger. 04
System Stop/Run Send RUN/STOP based on trigger. 05
Exact Turnout Feedback Message The AUX input is EXACT feedback. 0A
Output State and Sensor Input Message Send Both Feedback message and 
Output Message, on Output Change.
80
Send Output Message, Output Changed Send output msg.,  output changed. 81
Send Feedback Message, Output Message, and Message Type As well as message type defined by 
lower digit code.
82
Output State and Cascade Turnout Request 83
Exact Turnout Feedback Message The AUX. input is EXACT feedback. 8A

 
Local Route Chart
Outputs in Route 1st digit
Value
Outputs Closed 2nd digit 
Value
None 0x None (all Thrown/OFF) x0
A 1x A x1
B 2x B x2
A+B 3x A+B x3
C 4x C x4
A+C 5x A+C x5
B+C 6x B+C x6
A+B+C 7x A+B+C x7
D 8x D x8
A+D 9x A+D x9
B+D Ax B+D xA
A+B+D Bx A+B+D xB
C+D Cx C+D xC
A+C+D Dx A+C+D xD
C+B+D Ex C+B+D xE
A+B+C+D Fx A+B+C+D (all ON/CLOSED) xF

Specify all outputs you want thrown or closed in the first digit, then specify which turnouts you want closed in the second digit. Any output specified in the first digit, but not specified in the second digit will be thrown.


BACK